Museum & Library Exhibition Supplies in Singapore

In short: Inside a display case, two things damage objects: humidity that swings, and light that accumulates. Prosorb silica-gel cassettes and panels buffer relative humidity at a chosen set point; Elsec monitors and case hygrometers tell you what the environment is actually doing rather than what you assume. In Singapore’s climate, with ambient humidity routinely above 80% RH, both matter more than in temperate museums.

Specified for exhibition cases, framed works, cabinets and stores by museums, galleries and libraries across the region.

Start with the case

Buffer the humidity, then measure everything

Buffering without monitoring is guesswork; monitoring without buffering is just documentation of a problem. Cases normally need both.

Stabilising a display case

Museums and galleries mounting objects sensitive to humidity swings — wood, ivory, paper, lacquer, metals.

Recommended
Prosorb Cassettes

Silica gel preconditioned to your set point absorbs and releases moisture to hold RH steady as the room changes.

Framed works and shallow cases

Collections displaying paintings, works on paper and flat objects behind glass.

Recommended
Prosorb Panels (10 or 20 mm)

Thin enough to sit within a frame package or a shallow case base.

Light and UV surveys

Curators and conservators setting exposure limits and checking lamps, filters and daylight.

Recommended
Elsec 765

Lux, UV, temperature and RH in one handheld reading — the standard survey instrument.

Routine in-case readings

Collections staff doing walk-round checks without opening cases.

Recommended
Digital Thermo Hygrometer · Miniature Analogue Hygrometer

Small enough to sit discreetly in the case; the analogue unit needs no battery changes.

Sealing MDF case interiors

Exhibition designers and conservators building or refitting cases, plinths and shelving from MDF.

Recommended
Marvelseal 360 (10 m or 50 m roll)

Iron-on aluminium foil that stops board emissions reaching objects.

All products

Humidity control, monitoring and case lining

Humidity buffer Prosorb

Prosorb Humidity Control Cassettes

Silica-gel cassettes maintaining a stable relative humidity in display cases and cabinets; supplied preconditioned.

Request a quote →
Humidity buffer Prosorb

Prosorb Humidity Control Panels

Customisable silica-gel panels stabilising RH in painting frames and shallow showcases; priced by dimension.

Request a quote →
Monitor Elsec

Elsec 765 Environmental Monitor

Measures and displays visible light (lux or foot-candles), UV (mW/m² or µW/lumen), temperature and humidity in one instrument.

Request a quote →
Case instrument Micrographics Data

Digital Thermo Hygrometer

Miniature digital thermo-hygrometer for exhibition cases and cabinets.

Request a quote →
Case instrument Made in Japan

Miniature Analogue Hygrometer

Battery-free analogue hygrometer, 48 × 28 mm, for museum exhibition cases.

Request a quote →
Roll of Marvelseal 360 aluminium barrier foil
Barrier foil Marvelseal

Marvelseal 360 Barrier Foil

Iron-on aluminium composite foil for lining MDF in showcases; 121.9 cm wide, 10 m or 50 m rolls.

Request a quote →
Included with every system
Prosorb preconditioned to your nominated RH set point
Quantity calculation for your case volume
Panels cut to your dimensions
Advice on set point for Singapore’s climate
Delivery across Singapore
Environmental survey of cases and stores on request
What to control
Relative humidity — stability matters more than the exact figure
Visible light — lux and cumulative exposure
Ultraviolet — µW/lumen, filtered as far as possible
Temperature — drives RH inside a sealed case
Set points typically 45–55% RH for mixed collections
Procurement

Government agencies, statutory boards and public universities procure through GeBIZ, where Micrographics Data is a registered supplier. Tender-ready specifications and compliance statements are supplied on request.

Products vs. diagnosis

Buy the kit, or have us survey first

These are consumables and instruments — you buy them. What we can take on is the diagnosis: an environmental survey of your cases and stores, with readings, interpretation and a buffering specification.

FAQ

Controlling the display-case environment

Boxes, tissue and boards are under Archival Supplies; pest treatment under Nitrogen Anoxia.

What does Prosorb actually do?

It is silica gel conditioned to a specific relative humidity. Inside a reasonably sealed case it absorbs moisture when the air gets damper and releases it when the air dries, damping the swings that crack, cup and delaminate objects. It does not dehumidify a case — it buffers it.

What RH set point should we use in Singapore?

Mixed collections are commonly held around 50% RH, often 45–55%. The important thing is stability rather than the exact figure, and a set point that does not fight the building so hard that the buffer exhausts. Because ambient humidity here is routinely above 80% RH, case sealing and buffer quantity matter more than in temperate climates — tell us the case and we will calculate it.

Cassettes or panels?

Cassettes for display cases and cabinets where there is a base or plinth void to hide them. Panels — 10 or 20 mm, cut to size — for painting frames and shallow showcases with no depth to spare.

How much Prosorb does a case need?

It scales with case volume, how well the case is sealed and how far ambient conditions sit from your set point. Give us internal dimensions and the set point and we will calculate the quantity rather than guess.

Does Prosorb need reconditioning?

Yes, eventually — silica gel saturates. Reconditioning intervals depend on case sealing and ambient load, which is precisely why you also monitor: the hygrometer tells you when the buffer has stopped working.

What does the Elsec 765 measure?

Visible light in lux or foot-candles, UV in mW/m² or µW/lumen, plus temperature and relative humidity — the four readings a light-and-environment survey needs, in one handheld instrument.

Why measure UV separately from lux?

Damage is not proportional to brightness. UV degrades dyes, paper and textiles far out of proportion to how much it contributes to visible light, so a case can look correctly lit and still be damaging. UV is measured per lumen and filtered as far as possible.

Can you survey our cases for us?

Yes. We can take light, UV, temperature and humidity readings across your galleries and stores, interpret them against your collection types and specify buffering and filtering.

Do MDF display cases need lining?

Usually, yes. MDF can release formaldehyde and organic acids that build up inside a closed case. Lining exposed board with an iron-on barrier foil such as Marvelseal 360 seals those emissions away from objects.

Tell us your case volumes and target RH

We calculate the Prosorb quantity, nominate a set point, and quote monitors to match.